Heat Pump & Mini-Split Electrician in Vancouver, WA
- Circuit sized to the unit
- Works with your HVAC installer's schedule
- Urgent calls taken after hours
What Our Customers Say
Has Your Vancouver HVAC Installer Asked for a Circuit?
Getting a heat pump or mini-split? A Washington-licensed heat pump electrician handles the circuit, the disconnect and the panel check that comes first.
Two trades share a heat pump job. The HVAC installer handles the refrigerant side and sets the unit; the heat pump electrician handles the power. That means a dedicated 240-volt circuit for the outdoor unit, sized to the ratings on its nameplate, and a disconnect within sight of it, so the unit can be shut off without going indoors. The air handler gets its own circuit. A ductless system needs one circuit per outdoor unit, even if it serves one room.
The panel comes before any of it. In a local house, a heat pump that replaces a gas furnace adds a large 240-volt load, so we run a load calculation first. If the panel and service carry it, the circuit goes in with the main breaker off, Clark Public Utilities is not involved, and it is usually a same-day job. If they do not, the service is upgraded first under CPU's meter sequence: meter pulled, work done, inspection passed, and only then the meter set again.
How a Heat Pump Electrician Works in Vancouver
Read the nameplate
Ampacity and breaker size from the unit itself
Load calculation
House loads plus the new equipment, added up
Circuit or service?
The estimate says which, before we start
Circuit and disconnect
Run, mounted and connected at the unit
Sign-off, then run
We pull the permit; inspected before startup
Vancouver has 13,705 houses built in the 1970s and 9,864 built in the 1980s, their panels sized for the equipment of their day. When one of them trades a gas furnace for a heat pump, the load calculation decides whether the circuit is the whole job or the panel comes first.
Signs You Need a Heat Pump Electrician First
What Affects the Cost of Heat Pump Wiring in Vancouver
The nameplate and the panel decide most of this job; the number and placement of units do the rest.
Nameplate ratings
The ampacity and breaker size printed on the unit fix the circuit, so bigger equipment takes heavier wire.
Air handler circuit
A ducted system's indoor air handler usually needs its own run besides the outdoor unit's.
Ductless units
Each outdoor mini-split unit gets its own circuit and disconnect, even one that serves a single room.
Where the unit sits
An outdoor unit on the far side of the house from the panel needs a longer run.
1970s and 1980s panels
The city's 13,705 houses from the 1970s and 9,864 from the 1980s have panels sized for their day, so load math comes first.
CPU meter sequence
If the service must grow, CPU pulls the meter and sets it again only after the inspection passes.
Inspecting agency
The circuit is inspected by the city inside its limits or by Washington L&I outside them, depending on the address.
Every job gets a written estimate before any work starts.
Why Homeowners Here Call PWR Pro Electric
Nameplate read, not guessed
Breaker and wire match what the unit asks for
Licensed in Washington
L&I electrical contractor PWRPRPE749NP
Written estimate before any work begins
Whether the panel needs work, stated before we start
Questions Homeowners Ask
Who handles the Clark Public Utilities heat pump rebate?
Does a ductless mini-split need its own heat pump circuit?
Can the wiring go in before the heat pump arrives?
How long does it take to run a heat pump circuit?
Can we go over the estimate in Russian?
Book a Heat Pump Electrician in Vancouver, WA
Written estimate before any work begins.